Regulation · Code of Federal Regulations

40 C.F.R. Part 468 — COPPER FORMING POINT SOURCE CATEGORY

40 C.F.R. Part 468

Type
Regulation
Source
Code of Federal Regulations
Jurisdiction
Federal
Date
2026-08-20

§ 468.01 Applicability. (a) The provisions of this part are applicable to discharges resulting from the manufacture of formed copper and copper alloy products. The forming operations covered are hot rolling, cold rolling, drawing, extrusion and forging. This part does not regulate the forming of precious metals. (See 40 CFR part 471).

Citator

UpLaw has not yet analyzed 40 C.F.R. Part 468 — COPPER FORMING POINT SOURCE CATEGORY. The absence of a flag is not a finding that it is good law.

§ 468.01 Applicability. (a) The provisions of this part are applicable to discharges resulting from the manufacture of formed copper and copper alloy products. The forming operations covered are hot rolling, cold rolling, drawing, extrusion and forging. This part does not regulate the forming of precious metals. (See 40 CFR part 471). The casting of copper and copper alloys is not covered by this part. (See 40 CFR part 464). (b) The discharge allowance for drawing spent lubricant of 40 CFR 468.11(c), 468.14(c), and 468.15(c) are applicable only to those plants that actually discharge the drawing spent lubricant waste stream at copper forming sites. No discharge allowance is applicable or allowable where these wastewaters are hauled off-site for disposal or are otherwise not discharged at copper forming sites.

§ 468.02 Specialized definitions. In addition to the definitions set forth in 40 CFR part 401 and the chemical analysis methods in 40 CFR part 136, the following definitions apply to this part: (a) The term “alkaline cleaning bath” shall mean a bath consisting of an alkaline cleaning solution through which a workpiece is processed. (b) The term “alkaline cleaning rinse” shall mean a rinse following an alkaline cleaning bath through which a workpiece is processed. A rinse consisting of a series of rinse tanks is considered as a single rinse. (c) The term “ancillary operation” shall mean any operation associated with a primary forming operation. These ancillary operations include surface and heat treatment, hydrotesting, sawing, and surface coating. (d) The term “annealing with oil” shall mean the use of oil to quench a workpiece as it passes from an annealing furnace. (e) The term “annealing with water” shall mean the use of a water spray or bath, of which water is the major constituent, to quench a workpiece as it passes from an annealing furnace. (f) The term “cold rolling” shall mean the process of rolling a workpiece below the recrystallization temperature of the copper or copper alloy. (g) The term “drawing” shall mean pulling the workpiece through a die or succession of dies to reduce the diameter or alter its shape. (h) The term “extrusion” shall mean the application of pressure to a copper workpiece, forcing the copper to flow through a die orifice. (i) The term “extrusion heat treatment” shall mean the spray application of water to a workpiece immediately following extrusions for the purpose of heat treatment. (j) The term “heat treatment” shall mean the application or removal of heat to a workpiece to change the physical properties of the metal. (k) The term “pickling bath” shall mean any chemical bath (other than alkaline cleaning) through which a workpiece is processed. (l) The term “pickling fume scrubber” shall mean the process of using an air pollution control device to remove particulates and fumes from air above a pickling bath by entraining the pollutants in water. (m) The term “pickling rinse” shall mean a rinse, other than an alkaline cleaning rinse, through which a workpiece is processed. A rinse consisting of a series of rinse tanks is considered as a single rinse. (n) The term “off-kilogram (off-pound)” shall mean the mass of copper or copper alloy removed from a forming or ancillary operation at the end of a process cycle for transfer to a different machine or process. (o) The term “rolling” shall mean the reduction in the thickness or diameter of a workpiece by passing it between rollers. (p) The term “solution heat treatment” shall mean the process introducing a workpiece into a quench bath for the purpose of heat treatment following rolling, drawing or extrusion. (q) The term “spent lubricant” shall mean water or an oil-water mixture which is used in forming operations to reduce friction, heat and wear and ultimately discharged. (r) The term “Total Toxic Organics (TTO)” shall mean the sum of the masses or concentrations of each of the following toxic organic compounds which is found at a concentration greater than 0.010 mg/l. Benzene 1,1,1-Trichloroethane chloroform 2,6-Dinitrotoluene ethylbenzene methylene chloride napthalene N-nitrosodiphenylamine anthracene phenanthrene toluene trichloroethylene (s) The term “alkaline cleaning rinse for forged parts” shall mean a rinse following an alkaline cleaning bath through which a forged part is processed. A rinse consisting of a series of rinse tanks is considered as a single rinse. (t) The term “pickling rinse for forged parts” shall mean a rinse, other than an alkaline cleaning rinse, through which forged parts are processed. A rinse consisting of a series of rinse tanks is considered as a single rinse. (u) The term “tumbling or burnishing” shall mean the process of polishing, deburring, removing sharp corners, and generally smoothing parts for both cosmetic and functional purposes, as well as the process of washing the finished parts and cleaning the abrasion media. (v) The term “surface coating” shall mean the process of coating a copper workpiece as well as the associated surface finishing and flattening. (w) The term “miscellaneous waste stream” shall mean the following additional waste streams related to forming copper: hydrotesting, sawing, surface milling, and maintenance. (x) The term “precious metals” shall mean gold, platinum, palladium and silver and their alloys. Any alloy containing 30 or greater percent by weight of precious metals is considered a precious metal. (y) The term “beryllium copper alloy” shall mean any copper alloy that is alloyed to contain 0.10 percent or greater beryllium.

§ 468.03 Monitoring and reporting requirements. The following special monitoring requirements apply to all facilities controlled by this regulation. (a) The “monthly average” regulatory values shall be the basis for the monthly average discharge in direct discharge permits and for pretreatment standards. Compliance with the monthly discharge limit is required regardless of the number of samples analyzed and averaged. (b) As an alternate monitoring procedure for TTO, indirect dischargers may monitor for oil and grease and meet the alternate monitoring standards for oil and grease established for PSES and PSNS. Any indirect discharger meeting the alternate monitoring oil and grease standards shall be considered to meet the TTO standard.

§ 468.04 Compliance date for PSES. The compliance date for pretreatment standards for existing sources is August 15, 1986.

§ 468.10 Applicability; description of the copper forming subcategory. This subpart applies to discharges of pollutants to waters of the United States, and introduction of pollutants into publicly owned treatment works from the forming of copper and copper alloys except beryllium copper alloys.

§ 468.11 Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT). Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available: (a) Subpart A—Hot Rolling Spent Lubricant BPT Effluent Limitations. 1 Within the range of 7.5 to 10.0 at all times. (b) Subpart A—Cold Rolling Spent Lubricant BPT Effluent Limitations. 1 Within the range of 7.5 to 10.0 at all times. (c) Subpart A—Drawing Spent Lubricant BPT Effluent Limitations. 1 Within the range of 7.5 to 10.0 at all times. (d) Subpart A—Solution Heat Treatment BPT Effluent Limitations. 1 Within the range of 7.5 to 10.0 at all times. (e) Subpart A—Extrusion Heat Treatment BPT Effluent Limitations. 1 Within the range of 7.5 to 10.0 at all times. (f) Subpart A—Annealing With Water BPT Effluent Limitations. 1 Within the range of 7.5 to 10.0 at all times. (g) Subpart A—Annealing With Oil BPT Effluent Limitations. 1 Within the range of 7.5 to 10.0 at all times. (h) Subpart A—Alkaline Cleaning Rinse BPT Effluent Limitations. 1 Within the range of 7.5 to 10.0 at all times. (i) Subpart A—Alkaline Cleaning Rinse for Forged Parts BPT Effluent Limitations. 1 Within the range of 7.5 to 10.0 at all times. (j) Subpart A—Alkaline Cleaning Bath BPT Effluent Limitations. 1 Within the range of 7.5 to 10.0 at all times. (k) Subpart A—Pickling Rinse BPT Effluent Limitations. 1 Within the range of 7.5 to 10.0 at all times. (l) Subpart A—Pickling Rinse for Forged Parts BPT Effluent Limitations. 1 Within the range of 7.5 to 10.0 at all times. (m) Subpart A—Pickling Bath BPT Effluent Limitations. 1 Within the range of 7.5 to 10.0 at all times. (n) Subpart A—Pickling Fume Scrubber BPT Effluent Limitations. 1 Within the range of 7.5 to 10.0 at all times. (o) Subpart A—Tumbling or Burnishing BPT Effluent Limitations. 1 Within the range of 7.5 to 10.0 at all times. (p) Subpart A—Surface Coating BPT Effluent Limitations. 1 Within the range of 7.5 to 10.0 at all times. (q) Subpart A—Miscellaneous Waste Streams BPT Effluent Limitations. 1 Within the range of 7.5 to 10.0 at all times.

§ 468.12 Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable. Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent reduction attainable by the application of the best available technology economically achievable (BAT): (a) Subpart A—Hot Rolling Spent Lubricant BAT Effluent Limitations. (b) Subpart A—Cold Rolling Spent Lubricant BAT Effluent Limitations. (c) Subpart A—Drawing Spent Lubricant BAT Effluent Limitations. (d) Subpart A—Solution Heat Treatment BAT Effluent Limitations. (e) Subpart A—Extrusion Heat Treatment BAT Effluent Limitations. (f) Subpart A—Annealing with Water BAT Effluent Limitations. (g) Subpart A—Annealing with Oil BAT Effluent Limitations. (h) Subpart A—Alkaline Cleaning Rinse BAT Effluent Limitations. (i) Subpart A—Alkaline Cleaning Rinse for Forged Parts BAT Effluent Limitations. (j) Subpart A—Alkaline Cleaning Bath BAT Effluent Limitations. (k) Subpart A—Pickling Rinse BAT Effluent Limitations. (l) Subpart A—Pickling Rinse for Forged Parts BAT Effluent Limitations. (m) Subpart A—Pickling Bath BAT Effluent Limitations. (n) Subpart A—Pickling Fume Scrubber BAT Effluent Limitations. (o) Subpart A—Tumbling or Burnishing BAT Effluent Limitations. (p) Subpart A—Surface Coating BAT Effluent Limitations. (q) Subpart A—Miscellaneous Waste Streams BAT Effluent Limitations.

§ 468.13 New source performance standards (NSPS). The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: (a) Subpart A—Hot Rolling Spent Lubricant NSPS. 1 Within the range of 7.5 to 10.0 at all times. (b) Subpart A—Cold Rolling Spent Lubricant NSPS. 1 Within the range of 7.5 to 10.0 at all times. (c) Subpart A—Drawing Spent Lubricant NSPS. 1 Within the range of 7.5 to 10.0 at all times. (d) Subpart A—Solution Heat Treatment NSPS. 1 Within the range of 7.5 to 10.0 at all times. (e) Subpart A—Extrusion Heat Treatment NSPS. 1 Within the range of 7.5 to 10.0 at all times. (f) Subpart A—Annealing with Water NSPS. 1 Within the range of 7.5 to 10.0 at all times. (g) Subpart A—Annealing with Oil NSPS. 1 Within the range of 7.5 to 10.0 at all times. (h) Subpart A—Alkaline Cleaning Rinse NSPS. 1 Within the range of 7.5 to 10.0 at all times. (i) Subpart A—Alkaline Cleaning Rinse for Forged Parts NSPS. 1 Within the range of 7.5 to 10.0 at all times. (j) Subpart A—Alkaline Cleaning Bath NSPS. 1 Within the range of 7.5 to 10.0 at all times. (k) Subpart A—Pickling Rinse NSPS. 1 Within the range of 7.5 to 10.0 at all times. (l) Subpart A—Pickling Rinse for Forged Parts NSPS. 1 Within the range of 7.5 to 10.0 at all times. (m) Subpart A—Pickling Bath NSPS. 1 Within the range of 7.5 to 10.0 at all times. (n) Subpart A—Pickling Fume Scrubber NSPS. 1 Within the range of 7.5 to 10.0 at all times. (o) Subpart A—Tumbling or Burnishing NSPS. 1 Within the range of 7.5 to 10.0 at all times. (p) Subpart A—Surface Coating NSPS. 1 Within the range of 7.5 to 10.0 at all times. (q) Subpart A—Miscellaneous Waste Streams NSPS. Within the range of 7.5 to 10.0 at all times.

§ 468.14 Pretreatment standards for existing sources (PSES). Except as provided in 40 CFR 403.7 and 403.13, any existing source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for existing sources: (a) Subpart A—Hot Rolling Spent Lubricant PSES. 1 For alternate monitoring. (b) Subpart A—Cold Rolling Spent Lubricant PSES. 1 For alternate monitoring (c) Subpart A—Drawing Spent Lubricant PSES. 1 For alternate monitoring. (d) Subpart A—Solution Heat Treatment PSES. 1 For alternate monitoring. (e) Subpart A—Extrusion Heat Treatment PSES. 1 For alternate monitoring. (f) Subpart A—Annealing with Water PSES. 1 For alternate monitoring. (g) Subpart A—Annealing With Oil PSES. 1 For alternate monitoring. (h) Subpart A—Alkaline Cleaning Rinse PSES. 1 For alternate monitoring. (i) Subpart A—Alkaline Cleaning Rinse for Forged Parts PSES. 1 For alternate monitoring. (j) Subpart A—Alkaline Cleaning Bath PSES. 1 For alternate monitoring. (k) Subpart A—Pickling Rinse PSES. 1 For alternate monitoring. (l) Subpart A—Pickling Rinse for Forged Parts PSES. 1 For alternate monitoring. (m) Subpart A—Pickling Bath PSES. 1 For alternate monitoring. (n) Subpart A—Pickling Fume Scrubber PSES 1 For alternate monitoring. (o) Subpart A—Tumbling or Burnishing PSES. 1 For alternate monitoring. (p) Subpart A—Surface Coating PSES. 1 For alternate monitoring. (q) Subpart A—Miscellaneous Waste Streams PSES. 1 For alternate monitoring.

§ 468.15 Pretreatment standards for new sources (PSNS). Except as provided in 40 CFR 403.7, any new source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment sources for new sources: (a) Subpart A—Hot Rolling Spent Lubricant PSNS. 1 For alternate monitoring. (b) Subpart A—Cold Rolling Spent Lubricant PSNS. 1 For alternate monitoring. (c) Subpart A—Drawing Spent Lubricant PSNS. 1 For alternate monitoring. (d) Subpart A—Solution Heat Treatment PSNS. 1 For alternate monitoring. (e) Subpart A—Extrusion Heat Treatment PSNS. 1 For alternate monitoring. (f) Subpart A—Annealing with Water PSNS. 1 For alternate monitoring. (g) Subpart A—Annealing With Oil PSNS. 1 For alternate monitoring. (h) Subpart A—Alkaline Cleaning Rinse PSNS. 1 For alternate monitoring. (i) Subpart A—Alkaline Cleaning Rinse for Forged Parts PSNS. 1 For alternate monitoring. (j) Subpart A—Alkaline Cleaning Bath PSNS. 1 For alternate monitoring. (k) Subpart A—Pickling Rinse PSNS. 1 For alternate monitoring. (l) Subpart A—Pickling Rinse for Forged Parts PSNS. 1 For alternate monitoring. (m) Subpart A—Pickling Bath PSNS. 1 For alternate monitoring. (n) Subpart A—Pickling Fume Scrubber PSNS. 1 For alternate monitoring. (o) Subpart A—Tumbling or Burnishing PSNS. 1 For alternate monitoring. (p) Subpart A—Surface Coating PSNS. 1 For alternate monitoring. (q) Subpart A—Miscellaneous Waste Streams PSNS. 1 For alternate monitoring.

§ 468.16 Effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollution control technology (BCT). [Reserved]

§ 468.20 Applicability; description of the beryllium copper forming subcategory. This subpart applies to discharges of pollutants to waters of the United States, and introduction of pollutants into publicly owned treatment works from the forming of beryllium copper alloys.