GILBERT, Circuit Judge (after stating the facts as above). Concerning the. condition of the shaekle pin and the strain under which it broke, all the testimony on behalf of the appellant, with the exception of that of one expert, was heard before the court. There was evidence that the pin had been subjected to extraordinary strain in dragging a heavy slingload of lumber, estimated by the first officer of the ship to weigh 2% tons, a distance of 180 feet across the dock. An expert witness, who had been employed in the repair department of the Emergency Eleet Corporation, testified that in his judgment the pin- was in prime condition prior to what he characterized as the enormous pressure which broke it, that otherwise it would not have distorted the eye of the pin or drawn the jaws of the shackle out of parallel. The chief engineer of the Willamette Iron & Steel Works testified! that in his opinion the pin was a good piece of metal before it broke, and that its appearance indicated a tough and live metal.